<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-30 02-37-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 70 dBuV YLESUOMI
Pilot RDS Phase Difference
7.1 kHz 3.8 kHz 73 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 19200 1,2708
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,6 dBr 3,14 dBr 4,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 9 (Varied) 1 0 1 1 2:37, 30.10.2025
RT
-
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6205, 6201, 6202, 6207
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 1,2708 Acquired: 2025/10/30 2.36.42 Total samples: 19200 Equivalent time: 0:16:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,0 dBr MIN: 2,6 dBr AVE: 3,14 dBr % above 12,2 dBr: 0,0 Last value: 2,8 dBr (2025/10/30 2.36.41) 02.22 02.24 02.26 02.28 02.30 02.32 02.34 02.36 0 2 4 Pm [dBr]